Hydraulic Gear Pumps
- Simple and robust construction
- New principle of sealing the pump body
- Independent double side bearings
- New generation composite bushings
Hydraulic gear pumps are self aspirating external pumps. They are sued to generate a
flow of fluid and to impart the necessary forces to this flow.
Fluid
: Mineral oil to RE 07 075
Fluid temperature range : -15ºC to +80ºC
Viscosity range
: 10 to 300 mm²/s (recommended) 1000 mm²/s (permissible at start)
Degree of contamination : Permissible to NAS 1638 class 10. Filters with
a retention rate of at least ß20 >= 100
are recommended. Longer service may be achieved by filters type ß20 >= 100 to NAS
1638 class 9.
Drive
: Flexible couplings are recommended, proposals of any other types, inquirements
requested.
Installation
: Optional to the purpose.
Direction of rotation :
Subjected to be driven in the given direction of rotation.
Weights
: See table for the individual pump types.
Size |
4 |
6 |
7 |
8 |
9 |
11 |
14 |
16 |
17 |
20 |
24 |
28 |
34 |
Displacement
(volumetric) |
cm3/rev. |
4.4 |
6.3 |
7.0 |
8.2 |
9.5 |
11.3 |
14.0 |
15.8 |
17.8 |
20.8 |
23.9 |
27.9 |
34.4 |
L/min. |
6.6 |
9.5 |
10.5 |
12.3 |
14.3 |
17.0 |
21.0 |
23.7 |
26.7 |
31.2 |
35.9 |
41.9 |
51.6 |
Max.continuos pressure |
p1 bar |
210 |
210 |
210 |
210 |
210 |
210 |
210 |
210 |
210 |
200 |
150 |
150 |
120 |
Max. speed at p1 |
rpm |
4.000 |
4.000 |
4.000 |
4.000 |
3.000 |
2.700 |
4.000 |
3.800 |
3.400 |
2.900 |
2.600 |
2.200 |
1.800 |
Min. speed at p=180 bar |
rpm |
1.000 |
1.000 |
1.000 |
800 |
600 |
600 |
600 |
600 |
600 |
600 |
600 |
700 |
700 |
Min. speed at p1 |
rpm |
1.300 |
1.300 |
1.300 |
1.300 |
1.200 |
1.200 |
800 |
800 |
800 |
800 |
800 |
800 |
800 |
Operating inlet pressure (absolute) ?abs min
= 0,7 bar, ?abs max = 3,0 bar @ v = 41 mm²/s & t = 50ºC
Pump Outputs & Power Requirements (Average Values)
Size |
Type |
Nominal Volume cm³/rev |
Pressure p bar |
10 |
25 |
50 |
75 |
100 |
125 |
150 |
175 |
200 |
220 |
4 |
1D1-113... |
4,4 |
Q eft L/min |
6.4 |
6.3 |
6.3 |
6.3 |
6.2 |
6.2 |
6.1 |
6.0 |
6.0 |
6.0 |
P a kW |
0.4 |
0.6 |
0.8 |
1.1 |
1.5 |
1.8 |
2.2 |
2.5 |
2.8 |
3.1 |
T Nm |
2.6 |
4.1 |
5.7 |
7.4 |
9.5 |
11.4 |
13.4 |
15.3 |
17.2 |
18.9 |
6 |
1D1-120... |
6,3 |
Q eft L/min |
9.1 |
9.0 |
9.0 |
9.0 |
8.9 |
8.9 |
8.8 |
8.7 |
8.6 |
8.5 |
P a kW |
0.4 |
0.7 |
1.1 |
1.6 |
2.1 |
2.5 |
2.8 |
3.3 |
3.7 |
4.0 |
T Nm |
2.6 |
4.3 |
7.2 |
10.1 |
13.0 |
15.9 |
18.8 |
21.7 |
24.8 |
27.0 |
7 |
1D1-124... |
7 |
Q eft L/min |
10.0 |
10.0 |
9.9 |
9.9 |
9.8 |
9.8 |
9.7 |
9.6 |
9.6 |
9.5 |
P a kW |
0.4 |
0.7 |
1.2 |
1.8 |
2.3 |
2.7 |
3.1 |
3.6 |
4.1 |
4.4 |
T Nm |
2.9 |
4.9 |
8.1 |
11.3 |
14.5 |
17.8 |
21.0 |
24.2 |
27.6 |
30.2 |
8 |
1D1-128... |
8,2 |
Q eft L/min |
12.0 |
11.9 |
11.8 |
11.7 |
11.6 |
11.5 |
11.4 |
11.3 |
11.3 |
11.2 |
P a kW |
0.4 |
0.9 |
1.4 |
2.0 |
2.5 |
3.1 |
3.5 |
4.0 |
3.6 |
5.0 |
T Nm |
2.8 |
5.9 |
9.7 |
13.8 |
17.4 |
21.2 |
24.9 |
29.2 |
33.3 |
36.6 |
9 |
1D1-130... |
9,5 |
Q eft L/min |
13.8 |
13.8 |
13.7 |
13.6 |
13.4 |
13.3 |
13.2 |
13.1 |
13.0 |
13.0 |
P a kW |
0.4 |
0.9 |
1.4 |
2.1 |
2.7 |
3.3 |
3.9 |
4.4 |
5.1 |
5.6 |
T Nm |
3.3 |
6.9 |
11.4 |
16.0 |
20.3 |
24.7 |
29.0 |
33.9 |
38.8 |
42.6 |
11 |
1D1-136... |
11,3 |
Q eft L/min |
16.8 |
16.4 |
16.2 |
16.1 |
16.0 |
15.9 |
15.8 |
15.6 |
15.5 |
15.4 |
P a kW |
0.5 |
1.0 |
1.7 |
2.5 |
3.2 |
3.9 |
4.7 |
5.3 |
6.0 |
6.5 |
T Nm |
4.3 |
9.0 |
14.7 |
20.6 |
25.9 |
31.6 |
37.0 |
43.3 |
49.7 |
54.5 |
14 |
1D1-144... |
14 |
Q eft L/min |
20.6 |
20.4 |
20.2 |
20.1 |
19.9 |
19.7 |
19.6 |
19.3 |
19.2 |
19.1 |
P a kW |
0.7 |
1.3 |
2.1 |
3.0 |
3.9 |
4.9 |
5.7 |
6.5 |
7.3 |
8.2 |
T Nm |
5.0 |
10.1 |
15.2 |
21.0 |
29.6 |
36.4 |
42.3 |
49.2 |
55.4 |
60.0 |
16 |
1D1-152... |
15,8 |
Q eft L/min |
23.2 |
23.0 |
22.8 |
22.7 |
22.4 |
22.2 |
22.0 |
21.9 |
21.7 |
21.6 |
P a kW |
0.7 |
1.4 |
2.4 |
3.7 |
4.6 |
5.5 |
6.5 |
7.4 |
8.5 |
9.2 |
T Nm |
5.2 |
10.4 |
15.9 |
23.5 |
30.5 |
37.3 |
43.8 |
50.8 |
57.6 |
62.4 |
17 |
1D1-160... |
17,8 |
Q eft L/min |
26.1 |
26.0 |
25.8 |
25.6 |
25.3 |
25.1 |
24.9 |
24.8 |
24.7 |
24.7 |
P a kW |
0.8 |
1.7 |
2.7 |
3.8 |
5.1 |
6.2 |
7.4 |
8.5 |
9.5 |
10.6 |
T Nm |
5.8 |
11.8 |
18.0 |
26.5 |
34.4 |
42.1 |
49.3 |
57.3 |
65.0 |
71.5 |
20 |
1D1-162... |
20,8 |
Q eft L/min |
30.6 |
30.4 |
30.0 |
29.6 |
29.3 |
29.5 |
29.2 |
29.0 |
28.7 |
- |
P a kW |
1.0 |
2.0 |
3.1 |
4.4 |
5.8 |
7.2 |
8.6 |
9.8 |
11.0 |
- |
T Nm |
6.8 |
13.8 |
21.0 |
30.8 |
40.2 |
49.2 |
57.6 |
66.9 |
75.0 |
- |
24 |
1D1-172... |
23,9 |
Q eft L/min |
35.1 |
34.7 |
34.2 |
34.1 |
33.9 |
33.7 |
33.5 |
- |
- |
- |
P a kW |
1.1 |
2.4 |
3.3 |
5.0 |
6.6 |
8.1 |
9.7 |
- |
- |
- |
T Nm |
7.9 |
15.8 |
24.2 |
35.5 |
46.2 |
58.5 |
66.2 |
- |
- |
- |
28 |
1D1-190... |
27,9 |
Q eft L/min |
41.4 |
41.0 |
40.6 |
40.3 |
40.2 |
40.0 |
39.8 |
- |
- |
- |
P a kW |
1.3 |
2.7 |
3.9 |
5.9 |
7.8 |
9.6 |
- |
- |
- |
- |
T Nm |
7.8 |
15.8 |
24.1 |
35.6 |
46.2 |
56.5 |
- |
- |
- |
- |
34 |
1D1-200... |
34,4 |
Q eft L/min |
50.6 |
50.4 |
50.3 |
49.9 |
49.6 |
49.3 |
- |
- |
- |
- |
P a kW |
1.7 |
3.4 |
4.9 |
7.2 |
9.6 |
11.8 |
- |
- |
- |
- |
T
Nm |
9.6 |
19.6 |
29.8 |
44.0 |
57.1 |
69.7 |
- |
- |
- |
- |
Effective output flow (Q eff); required
drive power (P a) and Torque (T) at n = 1450 rpm, v = 41 mm²/s & t = 50ºC
For further information please